Views: 0 Author: Site Editor Publish Time: 2024-10-22 Origin: Site
In the volumetric lubricating system, each lubricating system must be provided with a quantified oil outlet hole of the corresponding volumetric distributor for through lubricating; otherwise, the pipeline cannot accumulate pressure, and the distributor cannot store or convey oil. The system shall be used with the lubricant pump, and cannot be used with the resistant lubricating pump.
Oil pipe orifices shall be cut in order to ensure that connection is integral without oil leakage; otherwise, the pipeline may leak oil and pressure cannot be accumulated, and the distributor cannot store oil or convey oil. When installed, interior of the pipeline shall be clean, and installing check valves in the lubricating pump and main pipeline are prohibited. Please use good quality clean oil. Unique, alkali or acid oil cannot be used. Applicable temperature -10~50℃. Please notice changes of environmental temperature. Properly adjust oil product variety. R32# oil product is used below the temperature of 15℃, and R68# oil product is used above 30℃.
Gear pump (Shaded Pole Motor): applicable for medium and smallsized machinery and equipment with main oil pipeline length of 10 meters, height of 6 meters and lubricating points of maximum 50 points. Gear pump (Induction Motor): applicable for various machinery and quipment with lengthy main oil pipe and requiring large oil quantities.